ASCS Cloud Download V128
QUICKSTARTDownload → verified → routed
Download V128

Lab WAN first · console attached · ~30 minutes

From zero to
routed.

The full first-run path with the commands and the click-by-click order: pick your install target, verify the media, boot, finish the first-boot wizard, bring up interfaces, DNS, DHCP, firewall, NAT and IPv6 — then take a backup before you touch anything for real.

Before anything else.

This is a preview. Use a lab WAN or an isolated upstream. Do not change the production WAN, reset the live router’s admin password, or cut over customers. Keep a console attached. If you only want to look, open the real console demo first — no install required. The full boundary is on the Boundaries & verification page and in the FAQ.

Step 0 — Choose your install target

PathBest forGet it
ASCS Cloud VPS imageTrying the real product in minutes. Virtual WAN/LAN NICs, nothing touches live ports. Snapshot-friendly.Deploy on a VPS · Cloud image guide
Installer ISOPhysical appliance or local VM. The supported path for hardware evaluation and the eventual production gate.Download Preview 128 · All versions
Proxmox / QEMU / virt-managerFree local lab with no cloud account. Attach the ISO as a CD-ROM, boot BIOS or UEFI, install to a virtual disk.Proxmox docs · QEMU docs · Hardware tiers

Minimum for the cloud image: 2 vCPU, 2 GB RAM, 16 GB disk, two virtual NICs (details). For physical hardware: Intel NICs and an SSD are the baseline — see the hardware guide before you buy, not after.

Step 1 — Download and verify the media

Verify before writing. The current preview publishes its SHA-256; archived releases also carry detached signatures and the release key.

# Download
curl -LO https://bridge.ascsonoway.com/assets/V5.3-REV-A-PREVIEW-128.iso
curl -LO https://bridge.ascsonoway.com/assets/V5.3-REV-A-PREVIEW-128.iso.sha256

# Verify the hash (must print OK / match)
sha256sum V5.3-REV-A-PREVIEW-128.iso
sha256sum -c V5.3-REV-A-PREVIEW-128.iso.sha256

# For archived releases (e.g. V124): signature + key
gpg --import ascs-release-key-107.asc
gpg --verify V5.3-REV-A-PREVIEW-124.iso.sha256.asc \
  V5.3-REV-A-PREVIEW-124.iso.sha256

Expected SHA-256 for Preview 128: e460a288c4038074e694e08828431846c26c02709e4e53701c0d09bf4a8e2807

Release keys are lab keys, not independently audited production identities. Verify the fingerprint out of band before trusting an image: DA0A737EFEAAFDCE0619510429BCACAE0FAA850D (V108+ key 107), 474E1ED2939FC62AF763A4B176BDBCD3D38E6734 (V104). See Boundaries & verification and Versions. Deep dives: sha256sum · GnuPG.

Step 2 — Write the installer media or mount it

  • USB: write the ISO with your tool of choice — dd on Linux (sudo dd if=V5.3-REV-A-PREVIEW-128.iso of=/dev/sdX bs=4M status=progress conv=fsync), Rufus (Windows), or balenaEtcher. Then confirm the write by booting it, not by hoping.
  • Proxmox: create a VM, attach the ISO as a CD-ROM on ide2, start it, and open Console. Do not bridge the VM’s WAN NIC to your production network for a first test — keep both NICs isolated.
  • BIOS vs UEFI: Preview 128 passed BIOS live boot in isolated QEMU; the UEFI path is retained from V110. Record which path you used — it goes in your acceptance evidence (deploy §11).
  • Disk selection: the disk installer requires destructive confirmation using the first six characters of the target boot-device serial (mirror installs need both prefixes), plus a separate typed ERASE. Read the prompt; it is designed to stop you installing onto the wrong disk.
  • Do not boot the installer USB on a machine whose disk you care about, “just to look.” Use the demo for looking.

Step 3 — Boot and pass the first-boot wizard

  1. Attach a serial console or keyboard/video. The appliance is designed to be recoverable without the web UI.
  2. Boot the ISO. Choose Install, select only the intended disk, and let it finish. Remove the ISO before the first installed boot.
  3. On first boot, the console shows a setup URL and, if claim flow is used, a setup code. Open the URL from a LAN client.
  4. Set the administrator username, display name, and a strong password. Confirm the WAN/LAN interface mapping before applying — the first-boot setup binds to the first enabled LAN interface by default.
  5. Sign in over HTTPS. HTTP (port 80 or 8080) redirects to HTTPS; a stray http://<lan-ip>:8443 also redirects cleanly. The default certificate is self-signed until you install your own (administrator manual · TLS) — do not expose the console to the WAN to silence the warning.

Addresses worth writing down now: WAN (eth0), LAN (eth1 · 10.10.0.1/24), an optional OPT/VLAN (eth1.50 · 10.50.0.1/24), IPv6 LAN (2001:db8:10::1/64 lab), DHCPv4 pool (10.10.0.100–10.10.0.199), and the management URL (https://10.10.0.1). The deployment guide §1 has the planning table.

Step 4 — Interfaces and segments

  • WAN: link the physical port, choose DHCP, static, or PPPoE, and confirm the default route appears. PPPoE is supported but not the first test — see the verification boundary for real-ISP PPPoE/PD.
  • LAN: set the LAN address and DHCP server. Management belongs on LAN/OPT only — never WAN.
  • OPT / VLAN: create the segment, assign the VLAN ID (1–4094), add firewall policy before connecting clients.
  • Use Interfaces (and, for remapping intent, the API’s POST /api/v1/interfaces/remap) to verify link state, addressing, and displayed DHCP/IPv6 mode. See interface captures.

NIC guidance — i210/i211/i225/i226 for 1 Gbps, i226-V for 2.5 Gbps, X710/82599/ConnectX for (unvalidated) 10 Gbps; avoid Realtek and USB Ethernet. Full matrix: hardware guide. Underlying links: nftables wiki · ip(8).

Step 5 — DNS and DHCP

  • Set upstream DNS servers under Settings — use resolvers you trust (yours, or public resolvers such as Quad9 9.9.9.9 / Cloudflare 1.1.1.1). quad9.net · 1.1.1.1
  • Set the LAN DHCP range and lease; keep the gateway and static servers outside the pool.
  • Add reservations for printers, access points, and management devices (/api/v1/dhcp-reservations, bulk at /api/v1/dhcp-reservations/bulk).
  • Test DNS Filters — block a test domain and confirm both the domain and its subdomains fail. Filters are applied through dnsmasq.

Step 6 — Firewall policy, NAT, aliases

  1. Create aliases (Host / Network / Port) for management hosts, servers, and common ports first — rules read better and diff smaller. See rule captures.
  2. Keep the default-deny posture; add explicit allow rules for LAN→WAN and required services. Use schedules if a rule only applies sometimes.
  3. Add port forwards or 1:1 NAT only after the base firewall works. Ports in 1–65535 or !5000 notation; source NAT and policy routes are available for multi-WAN designs (/api/v1/source-nats, /api/v1/policy-routes).
  4. Test from a client, not from the appliance. Check the audit log and per-rule counters.
  5. Stuck? Use Explain this flow (Diagnostics → firewall test) — the IPv4 forward-chain simulator traces a hypothetical flow through aliases, schedules, conntrack states, DNAT acceptance and the default drop, and tells you which rule fired. API: POST /api/v1/diagnostics/firewall-test (reference).

Dataplane details: nftables · conntrack-tools. Screenshots: port forwards · IPv4 rules · static routes.

Step 7 — IPv6

  • Lab first: a static LAN /64 and router advertisements; verify a client receives an address and a default route.
  • Stateless lets clients self-assign (SLAAC, RFC 4862); Stateful hands addresses from the segment /64 via DHCPv6 (RFC 8415).
  • For a real ISP, test DHCPv6-PD (RFC 3633) and the delegated prefix before enabling it on a production LAN — a lab /56 delegating a LAN /64 has been demonstrated.
  • Allow ICMPv6 (RFC 4443) and DHCPv6 in the IPv6 policy. Do not copy an IPv4-only ruleset blindly. See the boundary page for what is and isn’t verified.

Step 8 — Multi-WAN and traffic shaping (optional)

  • Give the primary WAN a lower route metric; backup gets a higher metric. Enable health checks only after the base WAN works; use a target reachable without split DNS.
  • Failover is tested by blocking the primary health target or disconnecting the lab WAN — confirm the route returns when it recovers.
  • Shaping applies to all active WAN interfaces: conservative upload/download limits, then verify with tc -s qdisc. Preview 128 adds granular HTB classes and flower filters (per interface, IP/CIDR, TCP/UDP port, direction, rate, ceiling, priority) on top of the WAN-wide default class — see administrator manual · shaping.

Theory: LARTC · tc-htb(8) · tc-flower(8).

Step 9 — Apps, then back up before anything for-real

  1. Open App Store and install one small app first. Confirm it starts, the port is reachable, and logs are visible. Then stop, start, and reinstall it before relying on it.
  2. Updates are signed application A/B slots with health supervision and rollback — not OS A/B. Failing slot? The supervisor restores the previous slot (administrator manual · updates).
  3. Download a configuration backup from Backups & Recovery and store it off the appliance — ASCS Cloud Storage (free 32 GB) is the one-click link-out. Keep the verified ISO and the per-install console password offline with it.
  4. Take the acceptance walk before production: reboot persistence, update apply/rollback, restore drill, port counters, BIOS/UEFI path recorded. It is all in deployment §11 and operations — and the evidence bar is on the status page.

Where this path bites people

TrapReality
“It boots, ship it”Booting in QEMU is not the physical hardware gate. Clean BIOS/UEFI install on the target appliance is still required for sign-off.
Management on WAN “just for setup”Never. LAN-only. If you need remote access, that’s a VPN, not an exposed console.
USB flash as the boot driveFails under logs, containers, and package updates. SSD or NVMe only — why.
“10G NICs ordered”The 10 Gbps tier is explicitly unvalidated — no line-rate claims without captures and error counters.
Resetting admin password “to test recovery”That decision loses the current configuration. Read the recovery card first.
Skipping the backupA backup never restored is only a hope. Do the restore drill on a lab unit while nothing is on fire — procedure.
Next stops.

The deep day-two procedures are in the administrator manual; the short version is operations; the order of operations is the deployment guide; the address plan and hardware sizing live in hardware; and the exit criteria are on status. Questions: FAQ · support@ascsonoway.com.