Lab WAN first · console attached · ~30 minutes
From zero to
routed.
The full first-run path with the commands and the click-by-click order: pick your install target, verify the media, boot, finish the first-boot wizard, bring up interfaces, DNS, DHCP, firewall, NAT and IPv6 — then take a backup before you touch anything for real.
This is a preview. Use a lab WAN or an isolated upstream. Do not change the production WAN, reset the live router’s admin password, or cut over customers. Keep a console attached. If you only want to look, open the real console demo first — no install required. The full boundary is on the Boundaries & verification page and in the FAQ.
Step 0 — Choose your install target
| Path | Best for | Get it |
|---|---|---|
| ASCS Cloud VPS image | Trying the real product in minutes. Virtual WAN/LAN NICs, nothing touches live ports. Snapshot-friendly. | Deploy on a VPS · Cloud image guide |
| Installer ISO | Physical appliance or local VM. The supported path for hardware evaluation and the eventual production gate. | Download Preview 128 · All versions |
| Proxmox / QEMU / virt-manager | Free local lab with no cloud account. Attach the ISO as a CD-ROM, boot BIOS or UEFI, install to a virtual disk. | Proxmox docs · QEMU docs · Hardware tiers |
Minimum for the cloud image: 2 vCPU, 2 GB RAM, 16 GB disk, two virtual NICs (details). For physical hardware: Intel NICs and an SSD are the baseline — see the hardware guide before you buy, not after.
Step 1 — Download and verify the media
Verify before writing. The current preview publishes its SHA-256; archived releases also carry detached signatures and the release key.
# Download
curl -LO https://bridge.ascsonoway.com/assets/V5.3-REV-A-PREVIEW-128.iso
curl -LO https://bridge.ascsonoway.com/assets/V5.3-REV-A-PREVIEW-128.iso.sha256
# Verify the hash (must print OK / match)
sha256sum V5.3-REV-A-PREVIEW-128.iso
sha256sum -c V5.3-REV-A-PREVIEW-128.iso.sha256
# For archived releases (e.g. V124): signature + key
gpg --import ascs-release-key-107.asc
gpg --verify V5.3-REV-A-PREVIEW-124.iso.sha256.asc \
V5.3-REV-A-PREVIEW-124.iso.sha256
Expected SHA-256 for Preview 128: e460a288c4038074e694e08828431846c26c02709e4e53701c0d09bf4a8e2807
Release keys are lab keys, not independently audited production identities. Verify the fingerprint out of band before trusting an image: DA0A737EFEAAFDCE0619510429BCACAE0FAA850D (V108+ key 107), 474E1ED2939FC62AF763A4B176BDBCD3D38E6734 (V104). See Boundaries & verification and Versions. Deep dives: sha256sum · GnuPG.
Step 2 — Write the installer media or mount it
- USB: write the ISO with your tool of choice —
ddon Linux (sudo dd if=V5.3-REV-A-PREVIEW-128.iso of=/dev/sdX bs=4M status=progress conv=fsync), Rufus (Windows), or balenaEtcher. Then confirm the write by booting it, not by hoping. - Proxmox: create a VM, attach the ISO as a CD-ROM on ide2, start it, and open Console. Do not bridge the VM’s WAN NIC to your production network for a first test — keep both NICs isolated.
- BIOS vs UEFI: Preview 128 passed BIOS live boot in isolated QEMU; the UEFI path is retained from V110. Record which path you used — it goes in your acceptance evidence (deploy §11).
- Disk selection: the disk installer requires destructive confirmation using the first six characters of the target boot-device serial (mirror installs need both prefixes), plus a separate typed
ERASE. Read the prompt; it is designed to stop you installing onto the wrong disk. - Do not boot the installer USB on a machine whose disk you care about, “just to look.” Use the demo for looking.
Step 3 — Boot and pass the first-boot wizard
- Attach a serial console or keyboard/video. The appliance is designed to be recoverable without the web UI.
- Boot the ISO. Choose Install, select only the intended disk, and let it finish. Remove the ISO before the first installed boot.
- On first boot, the console shows a setup URL and, if claim flow is used, a setup code. Open the URL from a LAN client.
- Set the administrator username, display name, and a strong password. Confirm the WAN/LAN interface mapping before applying — the first-boot setup binds to the first enabled LAN interface by default.
- Sign in over HTTPS. HTTP (port 80 or 8080) redirects to HTTPS; a stray
http://<lan-ip>:8443also redirects cleanly. The default certificate is self-signed until you install your own (administrator manual · TLS) — do not expose the console to the WAN to silence the warning.
Addresses worth writing down now: WAN (eth0), LAN (eth1 · 10.10.0.1/24), an optional OPT/VLAN (eth1.50 · 10.50.0.1/24), IPv6 LAN (2001:db8:10::1/64 lab), DHCPv4 pool (10.10.0.100–10.10.0.199), and the management URL (https://10.10.0.1). The deployment guide §1 has the planning table.
Step 4 — Interfaces and segments
- WAN: link the physical port, choose DHCP, static, or PPPoE, and confirm the default route appears. PPPoE is supported but not the first test — see the verification boundary for real-ISP PPPoE/PD.
- LAN: set the LAN address and DHCP server. Management belongs on LAN/OPT only — never WAN.
- OPT / VLAN: create the segment, assign the VLAN ID (1–4094), add firewall policy before connecting clients.
- Use Interfaces (and, for remapping intent, the API’s
POST /api/v1/interfaces/remap) to verify link state, addressing, and displayed DHCP/IPv6 mode. See interface captures.
NIC guidance — i210/i211/i225/i226 for 1 Gbps, i226-V for 2.5 Gbps, X710/82599/ConnectX for (unvalidated) 10 Gbps; avoid Realtek and USB Ethernet. Full matrix: hardware guide. Underlying links: nftables wiki · ip(8).
Step 5 — DNS and DHCP
- Set upstream DNS servers under Settings — use resolvers you trust (yours, or public resolvers such as Quad9
9.9.9.9/ Cloudflare1.1.1.1). quad9.net · 1.1.1.1 - Set the LAN DHCP range and lease; keep the gateway and static servers outside the pool.
- Add reservations for printers, access points, and management devices (
/api/v1/dhcp-reservations, bulk at/api/v1/dhcp-reservations/bulk). - Test DNS Filters — block a test domain and confirm both the domain and its subdomains fail. Filters are applied through dnsmasq.
Step 6 — Firewall policy, NAT, aliases
- Create aliases (Host / Network / Port) for management hosts, servers, and common ports first — rules read better and diff smaller. See rule captures.
- Keep the default-deny posture; add explicit allow rules for LAN→WAN and required services. Use schedules if a rule only applies sometimes.
- Add port forwards or 1:1 NAT only after the base firewall works. Ports in
1–65535or!5000notation; source NAT and policy routes are available for multi-WAN designs (/api/v1/source-nats,/api/v1/policy-routes). - Test from a client, not from the appliance. Check the audit log and per-rule counters.
- Stuck? Use Explain this flow (Diagnostics → firewall test) — the IPv4 forward-chain simulator traces a hypothetical flow through aliases, schedules, conntrack states, DNAT acceptance and the default drop, and tells you which rule fired. API:
POST /api/v1/diagnostics/firewall-test(reference).
Dataplane details: nftables · conntrack-tools. Screenshots: port forwards · IPv4 rules · static routes.
Step 7 — IPv6
- Lab first: a static LAN
/64and router advertisements; verify a client receives an address and a default route. - Stateless lets clients self-assign (SLAAC, RFC 4862); Stateful hands addresses from the segment
/64via DHCPv6 (RFC 8415). - For a real ISP, test DHCPv6-PD (RFC 3633) and the delegated prefix before enabling it on a production LAN — a lab /56 delegating a LAN /64 has been demonstrated.
- Allow ICMPv6 (RFC 4443) and DHCPv6 in the IPv6 policy. Do not copy an IPv4-only ruleset blindly. See the boundary page for what is and isn’t verified.
Step 8 — Multi-WAN and traffic shaping (optional)
- Give the primary WAN a lower route metric; backup gets a higher metric. Enable health checks only after the base WAN works; use a target reachable without split DNS.
- Failover is tested by blocking the primary health target or disconnecting the lab WAN — confirm the route returns when it recovers.
- Shaping applies to all active WAN interfaces: conservative upload/download limits, then verify with
tc -s qdisc. Preview 128 adds granular HTB classes and flower filters (per interface, IP/CIDR, TCP/UDP port, direction, rate, ceiling, priority) on top of the WAN-wide default class — see administrator manual · shaping.
Theory: LARTC · tc-htb(8) · tc-flower(8).
Step 9 — Apps, then back up before anything for-real
- Open App Store and install one small app first. Confirm it starts, the port is reachable, and logs are visible. Then stop, start, and reinstall it before relying on it.
- Updates are signed application A/B slots with health supervision and rollback — not OS A/B. Failing slot? The supervisor restores the previous slot (administrator manual · updates).
- Download a configuration backup from Backups & Recovery and store it off the appliance — ASCS Cloud Storage (free 32 GB) is the one-click link-out. Keep the verified ISO and the per-install console password offline with it.
- Take the acceptance walk before production: reboot persistence, update apply/rollback, restore drill, port counters, BIOS/UEFI path recorded. It is all in deployment §11 and operations — and the evidence bar is on the status page.
Where this path bites people
| Trap | Reality |
|---|---|
| “It boots, ship it” | Booting in QEMU is not the physical hardware gate. Clean BIOS/UEFI install on the target appliance is still required for sign-off. |
| Management on WAN “just for setup” | Never. LAN-only. If you need remote access, that’s a VPN, not an exposed console. |
| USB flash as the boot drive | Fails under logs, containers, and package updates. SSD or NVMe only — why. |
| “10G NICs ordered” | The 10 Gbps tier is explicitly unvalidated — no line-rate claims without captures and error counters. |
| Resetting admin password “to test recovery” | That decision loses the current configuration. Read the recovery card first. |
| Skipping the backup | A backup never restored is only a hope. Do the restore drill on a lab unit while nothing is on fire — procedure. |
The deep day-two procedures are in the administrator manual; the short version is operations; the order of operations is the deployment guide; the address plan and hardware sizing live in hardware; and the exit criteria are on status. Questions: FAQ · support@ascsonoway.com.